Reply: device,0,0 %adevice,1,1 IRTRIPORT_BLASTERendlistdevicesVariables: One line per module, each ending CR, then endlistdevices. %a = ETHERNET, WIFI. A Flex always reports one port on module 1, whatever the cable carriesEnding: cr
GET FIRMWARE VERSIONgetversion
Reply: %vVariables: %v = firmware part number and version, for example 710-3000-21Ending: cr
Reply: IR,1:1,%aVariables: %a = IR, IR_BLASTER, IRTRIPORT, IRTRIPORT_BLASTER, SERIAL, SENSOR, SENSOR_NOTIFY. The port is always 1Ending: cr
SET MODE IR_BLASTERset_IR,1:1,IRTRIPORT_BLASTER
Reply: IR,1:1,IRTRIPORT_BLASTERVariables: Class commands for any other mode then return ERR 005Ending: cr
SEND IR 1sendir,1:1,%i,%f,%r,%o,%c
Reply: completeir,1:1,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-20 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 4-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
SEND IR 2sendir,1:2,%i,%f,%r,%o,%c
Reply: completeir,1:2,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-20 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 4-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
SEND IR 3sendir,1:3,%i,%f,%r,%o,%c
Reply: completeir,1:3,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-20 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 4-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
STOP IR 1stopir,1:1
Reply: stopir,1:1Variables: Also echoed to the client whose transmission was stoppedEnding: cr
STOP IR 2stopir,1:2
Reply: stopir,1:2Variables: Also echoed to the client whose transmission was stoppedEnding: cr
STOP IR 3stopir,1:3
Reply: stopir,1:3Variables: Also echoed to the client whose transmission was stoppedEnding: cr
Cheat sheet
driver.cheatSheet()
What it is
A Global Cache Flex on the FLC-2E1B cable sends IR from two emitters and a blaster on port 3. It is the Flex factory default mode.
Specs
Type: 2 IR emitters and 1 blaster on a Flex Link cable (FLC-2E1B, FLC-T3 with two G-IR-E and FLC-BL)
Inputs: 2x IR emitters, 1x IR blaster
Mounting: Desktop or surface
Setup
First Use: This is the factory default mode, so a Flex found on the network is offered as this model until GET DEVICE MODE says otherwise. Works on a Flex IP, Flex IP PoE or Flex WiFi base unit. The cable mode, not the base unit, decides which commands answer. With no DHCP server a Flex IP takes 192.168.1.70. Up to 8 clients on port 4998.
Support
Tech Support Phone: 541-899-4800
Power Cycle: Remove power for ten seconds. Relay states return to open after a reset or power cycle.
About this driver
driver.source()
Confirm each command on your device before you rely on it. Provided as is, with no warranty. To correct something or ask for it to come down, write to info@ctrlbot.io. Licensed CC BY 4.0: credit CTRLbot and link back when you share it. Product page. Manufacturer site.