GLOBAL CACHE, End Points
GLOBAL CACHE, End Points
getdevices
get_SERIAL,1:1
set_SERIAL,1:1,%g,FLOW_%h,PARITY_%i,STOPBITS_%j
getversion
get_NET,0:1
The Global Cache Global Connect serial module puts one RS-232 port on the network. Serial data crosses TCP port 4999 unchanged, and the port's settings are read and set on port 4998.
Type: Global Connect RS-232 module
Inputs: 1x RS-232
Mounting: Global Connect chassis
First Use: With no DHCP server after two minutes the module takes 192.168.1.70 plus its chassis position. Serial data crosses TCP 4999; plan for 4 clients there, since documents give 4 or 8. Each module is its own device with its own IP address. Up to 8 clients on port 4998; opening one more closes the oldest. The factory baud rate is 19200 in the API table and 115200 in every example; read it with GET SERIAL CONFIG.
Tech Support Phone: 541-899-4800
Power Cycle: Remove power for ten seconds. Relay states return to open after a reset or power cycle.
Confirm each command on your device before you rely on it. Provided as is, with no warranty. To correct something or ask for it to come down, write to info@ctrlbot.io. Licensed CC BY 4.0: credit CTRLbot and link back when you share it. Product page. Manufacturer site.