Reply: completeir,1:1,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-50 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 1-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
SEND IR 2sendir,1:2,%i,%f,%r,%o,%c
Reply: completeir,1:2,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-50 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 1-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
SEND IR 3sendir,1:3,%i,%f,%r,%o,%c
Reply: completeir,1:3,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-50 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 1-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
STOP IR 1stopir,1:1
Reply: stopir,1:1Variables: Also echoed to the client whose transmission was stoppedEnding: cr
STOP IR 2stopir,1:2
Reply: stopir,1:2Variables: Also echoed to the client whose transmission was stoppedEnding: cr
STOP IR 3stopir,1:3
Reply: stopir,1:3Variables: Also echoed to the client whose transmission was stoppedEnding: cr
Reply: IR,1:3,%aVariables: %a = IR, IR_BLASTER (port 3 only), SENSOR, SENSOR_NOTIFY, LED_LIGHTING. IR_BLASTER on port 1 or 2 returns ERR_1:1,014Ending: cr
GET SENSOR_STATE 1getstate,1:1
Reply: state,1:1,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 2getstate,1:2
Reply: state,1:2,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 3getstate,1:3
Reply: state,1:3,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr
Cheat sheet
driver.cheatSheet()
What it is
The Global Cache iTach IP2IR puts three IR ports on the network over Ethernet. Each port is an IR emitter output or a contact sensor input, and the third can drive a blaster.
Specs
Type: IR to Ethernet adapter, 3 IR or sensor ports
Inputs: 3x 3.5 mm IR or sensor ports
Mounting: Desktop
Setup
First Use: With no DHCP server the unit takes 192.168.1.70. Up to 8 clients on port 4998.
Support
Tech Support Phone: 541-899-4800
Power Cycle: Remove power for ten seconds. Relay states return to open after a reset or power cycle.
About this driver
driver.source()
Confirm each command on your device before you rely on it. Provided as is, with no warranty. To correct something or ask for it to come down, write to info@ctrlbot.io. Licensed CC BY 4.0: credit CTRLbot and link back when you share it. Product page. Manufacturer site.