GLOBAL CACHE, End Points
GLOBAL CACHE, End Points
getdevices
get_SERIAL,1:1
set_SERIAL,1:1,%g,FLOW_%h,PARITY_%i
getversion
get_NET,0:1
The Global Cache iTach IP2SL puts one RS-232 port on the network over Ethernet. Serial data crosses TCP port 4999 unchanged, and the port's settings are read and set on the Unified TCP API port 4998.
Type: RS-232 to Ethernet adapter
Inputs: 1x DB9 RS-232
Mounting: Desktop
First Use: With no DHCP server the unit takes 192.168.1.70. Serial data crosses TCP 4999, up to 4 clients only with Serial Multiconnection Mode enabled on the web page. Up to 8 clients on port 4998.
Tech Support Phone: 541-899-4800
Power Cycle: Remove power for ten seconds. Relay states return to open after a reset or power cycle.
Confirm each command on your device before you rely on it. Provided as is, with no warranty. To correct something or ask for it to come down, write to info@ctrlbot.io. Licensed CC BY 4.0: credit CTRLbot and link back when you share it. Product page. Manufacturer site.