Flex Relay Sensor

Control
IP
Encoding
ASCII
IP
TCP port 4998
Line ending
CR
Roles
End point

Commands

33 commands
OTHER33
GET DEVICE MODE getdevices
Reply: device,0,0 %adevice,1,1 RELAYSENSORendlistdevicesVariables: One line per module, each ending CR, then endlistdevices. %a = ETHERNET, WIFI. A Flex always reports one port on module 1, whatever the cable carries. Sensors on module 2 are not listed (a known bug)Ending: cr
OPEN RELAY 1 setstate,1:1,0
Reply: state,1:1,0Variables: A relay must be configured with SET RELAY_TYPE before it switchesEnding: cr
OPEN RELAY 2 setstate,1:2,0
Reply: state,1:2,0Variables: A relay must be configured with SET RELAY_TYPE before it switchesEnding: cr
OPEN RELAY 3 setstate,1:3,0
Reply: state,1:3,0Variables: A relay must be configured with SET RELAY_TYPE before it switchesEnding: cr
OPEN RELAY 4 setstate,1:4,0
Reply: state,1:4,0Variables: A relay must be configured with SET RELAY_TYPE before it switchesEnding: cr
CLOSE RELAY 1 setstate,1:1,1
Reply: state,1:1,1Variables: A relay must be configured with SET RELAY_TYPE before it switchesEnding: cr
CLOSE RELAY 2 setstate,1:2,1
Reply: state,1:2,1Variables: A relay must be configured with SET RELAY_TYPE before it switchesEnding: cr
CLOSE RELAY 3 setstate,1:3,1
Reply: state,1:3,1Variables: A relay must be configured with SET RELAY_TYPE before it switchesEnding: cr
CLOSE RELAY 4 setstate,1:4,1
Reply: state,1:4,1Variables: A relay must be configured with SET RELAY_TYPE before it switchesEnding: cr
GET FIRMWARE VERSION getversion
Reply: %vVariables: %v = firmware part number and version, for example 710-3000-21Ending: cr
GET NETWORK get_NET,0:1
Reply: NET,0:1,%a,%b,%c,%d,%eVariables: %a = UNLOCKED, LOCKED %b = DHCP, STATIC %c = IP address %d = subnet mask %e = gatewayEnding: cr
GET CABLE MODE get_RELAYSENSOR,1:1
Reply: RELAYSENSOR,1:1,%aVariables: %a = 4R4S. Documented in the Flex API 1.6 onlyEnding: cr
SET MODE RELAY_SENSOR set_RELAYSENSOR,1:1
Reply: RELAYSENSOR,1:1Variables: Documented in the Flex API 1.6 only; the Unified API has no command that selects the relay and sensor cableEnding: cr
GET RELAY_STATE 1 getstate,1:1
Reply: state,1:1,%sVariables: %s = 0 open, 1 closedEnding: cr
GET RELAY_STATE 2 getstate,1:2
Reply: state,1:2,%sVariables: %s = 0 open, 1 closedEnding: cr
GET RELAY_STATE 3 getstate,1:3
Reply: state,1:3,%sVariables: %s = 0 open, 1 closedEnding: cr
GET RELAY_STATE 4 getstate,1:4
Reply: state,1:4,%sVariables: %s = 0 open, 1 closedEnding: cr
PULSE RELAY 1 setstate,1:1,1,%t
Reply: state,1:1,1Variables: %t = hold time 1-4294967295 ms, then the relay returns to its previous state. Firmware 22 and laterEnding: cr
PULSE RELAY 2 setstate,1:2,1,%t
Reply: state,1:2,1Variables: %t = hold time 1-4294967295 ms, then the relay returns to its previous state. Firmware 22 and laterEnding: cr
PULSE RELAY 3 setstate,1:3,1,%t
Reply: state,1:3,1Variables: %t = hold time 1-4294967295 ms, then the relay returns to its previous state. Firmware 22 and laterEnding: cr
PULSE RELAY 4 setstate,1:4,1,%t
Reply: state,1:4,1Variables: %t = hold time 1-4294967295 ms, then the relay returns to its previous state. Firmware 22 and laterEnding: cr
GET RELAY_TYPE 1 get_RELAY,1:1
Reply: RELAY,1:1,%tVariables: %t = SPST, SPDT, DPDT, Disabled, UnavailableEnding: cr
SET RELAY_TYPE 1 set_RELAY,1:1,%t
Reply: RELAY,1:1,%tVariables: %t = SPST, SPDT, DPDT, Disabled. SPDT takes two ports and DPDT four, starting at an odd port. Set every affected port to Disabled first, or no change is applied and an error is returnedEnding: cr
GET RELAY_TYPE 2 get_RELAY,1:2
Reply: RELAY,1:2,%tVariables: %t = SPST, SPDT, DPDT, Disabled, UnavailableEnding: cr
SET RELAY_TYPE 2 set_RELAY,1:2,%t
Reply: RELAY,1:2,%tVariables: %t = SPST, SPDT, DPDT, Disabled. SPDT takes two ports and DPDT four, starting at an odd port. Set every affected port to Disabled first, or no change is applied and an error is returnedEnding: cr
GET RELAY_TYPE 3 get_RELAY,1:3
Reply: RELAY,1:3,%tVariables: %t = SPST, SPDT, DPDT, Disabled, UnavailableEnding: cr
SET RELAY_TYPE 3 set_RELAY,1:3,%t
Reply: RELAY,1:3,%tVariables: %t = SPST, SPDT, DPDT, Disabled. SPDT takes two ports and DPDT four, starting at an odd port. Set every affected port to Disabled first, or no change is applied and an error is returnedEnding: cr
GET RELAY_TYPE 4 get_RELAY,1:4
Reply: RELAY,1:4,%tVariables: %t = SPST, SPDT, DPDT, Disabled, UnavailableEnding: cr
SET RELAY_TYPE 4 set_RELAY,1:4,%t
Reply: RELAY,1:4,%tVariables: %t = SPST, SPDT, DPDT, Disabled. SPDT takes two ports and DPDT four, starting at an odd port. Set every affected port to Disabled first, or no change is applied and an error is returnedEnding: cr
GET SENSOR_STATE 1 getstate,2:1
Reply: state,2:1,%sVariables: %s = 0, 1. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 2 getstate,2:2
Reply: state,2:2,%sVariables: %s = 0, 1. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 3 getstate,2:3
Reply: state,2:3,%sVariables: %s = 0, 1. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 4 getstate,2:4
Reply: state,2:4,%sVariables: %s = 0, 1. Polarity differs by document, so read the value, not a labelEnding: cr

Cheat sheet

driver.cheatSheet()

What it is

A Global Cache Flex on the FLC-RS cable has four relays and four sensor inputs. The relays combine into SPST, SPDT or DPDT switches.

Specs

Type: 4 relays and 4 sensors on a Flex Link cable (FLC-RS)

Inputs: 4x relays, SPST normally open, 24 V AC/DC 0.5 A; 4x sensor inputs

Mounting: Desktop or surface

Setup

First Use: Set the cable mode with SET MODE RELAY_SENSOR. Every relay is Disabled at power-on: set each relay with SET RELAY_TYPE before switching it. Sensors are on module 2. Works on a Flex IP, Flex IP PoE or Flex WiFi base unit. The cable mode, not the base unit, decides which commands answer. With no DHCP server a Flex IP takes 192.168.1.70. Up to 8 clients on port 4998.

Support

Tech Support Phone: 541-899-4800

Power Cycle: Remove power for ten seconds. Relay states return to open after a reset or power cycle.