GLOBAL CACHE, End Points
GLOBAL CACHE, End Points
getdevices
set_IR,1:1,SERIAL
get_SERIAL,1:1
set_SERIAL,1:1,%g,DUPLEX_%h,PARITY_%i,STOPBITS_%j,CABLE_4
getversion
get_NET,0:1
get_IR,1:1
A Global Cache Flex on the RS-485 serial cable puts one two-wire or four-wire RS-485 port on the network. Serial data crosses TCP port 4999 unchanged.
Type: RS-485 on a Flex Link cable (FLC-SL-485)
Inputs: 1x RS-485 terminal block
Mounting: Desktop or surface
First Use: Set the cable mode with SET MODE SERIAL, then SET SERIAL CONFIG with DUPLEX HALF or FULL. Serial data crosses TCP 4999. Works on a Flex IP, Flex IP PoE or Flex WiFi base unit. The cable mode, not the base unit, decides which commands answer. With no DHCP server a Flex IP takes 192.168.1.70. Up to 8 clients on port 4998.
Tech Support Phone: 541-899-4800
Power Cycle: Remove power for ten seconds. Relay states return to open after a reset or power cycle.
Confirm each command on your device before you rely on it. Provided as is, with no warranty. To correct something or ask for it to come down, write to info@ctrlbot.io. Licensed CC BY 4.0: credit CTRLbot and link back when you share it. Product page. Manufacturer site.