GLOBAL CACHE, End Points

GC-100-06

Control
IP
Encoding
ASCII
IP
TCP port 4998
Line ending
CR
Roles
End point
Discovery
GLOBALCACHE

Commands

22 commands
OTHER22
GET DEVICE MODE getdevices
Reply: device,1,1 SERIALdevice,2,3 IRendlistdevicesVariables: One line per module, each ending CR, then endlistdevices. Derived, not printed in any source: module 2 is inferred from the GC-100 IR module list and position numberingEnding: cr
GET SERIAL CONFIG get_SERIAL,1:1
Reply: SERIAL,1:1,%b,FLOW_%c,PARITY_%eVariables: %b = 1200, 2400, 4800, 9600, 19200, 38400, 57600 %c = NONE, HARDWARE %e = NO, EVEN, ODDEnding: cr
SET SERIAL CONFIG set_SERIAL,1:1,%g,FLOW_%h,PARITY_%i
Reply: SERIAL,1:1,%g,FLOW_%h,PARITY_%iVariables: %g = 1200, 2400, 4800, 9600, 19200, 38400, 57600 %h = NONE, HARDWARE %i = NO, EVEN, ODDEnding: cr
GET FIRMWARE VERSION getversion
Reply: version,0,%vVariables: %v = firmware version, for example 3.2-12Ending: cr
GET NETWORK get_NET,0:1
Reply: NET,0:1,%a,%b,%c,%d,%eVariables: %a = UNLOCKED, LOCKED %b = DHCP, STATIC %c = IP address %d = subnet mask %e = gatewayEnding: cr
BLINK ON blink,1
Variables: No reply. Starts a continuous blink of the power LEDEnding: cr
BLINK OFF blink,0
Variables: No reply. Stops the blink (the default)Ending: cr
SEND IR 1 sendir,2:1,%i,%f,%r,%o,%c
Reply: completeir,2:1,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 20000-500000 Hz %r = repeat 1-31 %o = offset, odd, 1-255 %c = on,off pulse counts in carrier cycles, 1-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
SEND IR 2 sendir,2:2,%i,%f,%r,%o,%c
Reply: completeir,2:2,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 20000-500000 Hz %r = repeat 1-31 %o = offset, odd, 1-255 %c = on,off pulse counts in carrier cycles, 1-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
SEND IR 3 sendir,2:3,%i,%f,%r,%o,%c
Reply: completeir,2:3,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 20000-500000 Hz %r = repeat 1-31 %o = offset, odd, 1-255 %c = on,off pulse counts in carrier cycles, 1-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
STOP IR 1 stopir,2:1
Variables: No reply. Halts at the end of the current timing patternEnding: cr
STOP IR 2 stopir,2:2
Variables: No reply. Halts at the end of the current timing patternEnding: cr
STOP IR 3 stopir,2:3
Variables: No reply. Halts at the end of the current timing patternEnding: cr
GET PORT_MODE 1 get_IR,2:1
Reply: IR,2:1,%aVariables: %a = IR, BL2_BLASTER, IR_NOCARRIER, SENSOR, SENSOR_NOTIFYEnding: cr
SET PORT_MODE 1 set_IR,2:1,%a
Reply: IR,2:1,%aVariables: %a = IR, BL2_BLASTER, IR_NOCARRIER, SENSOR, SENSOR_NOTIFY. The GC-100 resets after a successful set_IR, keeping the TCP connection (soft reset, RN-G 3.0)Ending: cr
GET PORT_MODE 2 get_IR,2:2
Reply: IR,2:2,%aVariables: %a = IR, BL2_BLASTER, IR_NOCARRIER, SENSOR, SENSOR_NOTIFYEnding: cr
SET PORT_MODE 2 set_IR,2:2,%a
Reply: IR,2:2,%aVariables: %a = IR, BL2_BLASTER, IR_NOCARRIER, SENSOR, SENSOR_NOTIFY. The GC-100 resets after a successful set_IR, keeping the TCP connection (soft reset, RN-G 3.0)Ending: cr
GET PORT_MODE 3 get_IR,2:3
Reply: IR,2:3,%aVariables: %a = IR, BL2_BLASTER, IR_NOCARRIER, SENSOR, SENSOR_NOTIFYEnding: cr
SET PORT_MODE 3 set_IR,2:3,%a
Reply: IR,2:3,%aVariables: %a = IR, BL2_BLASTER, IR_NOCARRIER, SENSOR, SENSOR_NOTIFY. The GC-100 resets after a successful set_IR, keeping the TCP connection (soft reset, RN-G 3.0)Ending: cr
GET SENSOR_STATE 1 getstate,2:1
Reply: state,2:1,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 2 getstate,2:2
Reply: state,2:2,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 3 getstate,2:3
Reply: state,2:3,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr

Cheat sheet

driver.cheatSheet()

What it is

The Global Cache GC-100-06 network adapter has one RS-232 port and three IR ports, each usable as an IR emitter output or a sensor input. It accepts one TCP client at a time on the Unified TCP API port 4998.

Specs

Type: Network adapter, 1 serial port and 3 IR or sensor ports

Inputs: 1x DB9 RS-232, 3x 3.5 mm IR or sensor ports

Mounting: Desktop or rack shelf

Setup

First Use: With no DHCP server the unit takes 192.168.1.70. Serial data crosses TCP 4999. The GC-100 accepts one TCP client on port 4998, and one per serial port. What happens to a second client is not documented. The IR module address 2 is derived; confirm it with GET DEVICE MODE on first connect.

Support

Tech Support Phone: 541-899-4800

Power Cycle: Remove power for ten seconds. Relay states return to open after a reset or power cycle.