Reply: device,0,0 MODULEdevice,1,3 IRendlistdevicesVariables: One line per module, each ending CR, then endlistdevices. The IR type may carry a subtype, for example IR_OUTEnding: cr
GET FIRMWARE VERSIONgetversion
Reply: %vVariables: %v = firmware part number and version, for example 710-3000-21Ending: cr
Reply: completeir,1:1,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-20 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 4-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
SEND IR 2sendir,1:2,%i,%f,%r,%o,%c
Reply: completeir,1:2,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-20 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 4-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
SEND IR 3sendir,1:3,%i,%f,%r,%o,%c
Reply: completeir,1:3,%iVariables: %i = ID 0-65535, echoed in completeir %f = carrier 15000-500000 Hz %r = repeat 1-20 %o = offset, odd, 1-383 %c = on,off pulse counts in carrier cycles, 4-50000 each, in pairs. Reply may be busyir (U), or busyIR,<m>:<p>,<ID> on older firmware, when the port is sending a different codeEnding: cr
STOP IR 1stopir,1:1
Reply: stopir,1:1Variables: Also echoed to the client whose transmission was stoppedEnding: cr
STOP IR 2stopir,1:2
Reply: stopir,1:2Variables: Also echoed to the client whose transmission was stoppedEnding: cr
STOP IR 3stopir,1:3
Reply: stopir,1:3Variables: Also echoed to the client whose transmission was stoppedEnding: cr
Reply: state,1:1,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 2getstate,1:2
Reply: state,1:2,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr
GET SENSOR_STATE 3getstate,1:3
Reply: state,1:3,%sVariables: %s = 0, 1. The port must be set to SENSOR or SENSOR_NOTIFY first. Polarity differs by document, so read the value, not a labelEnding: cr
Cheat sheet
driver.cheatSheet()
What it is
The Global Cache Global Connect IR module has three ports, each an IR emitter output or a sensor input, and the third can drive a blaster. Commands use the Unified TCP API on port 4998.
Specs
Type: Global Connect IR and sensor module, 3 ports
Inputs: 3x 3.5 mm IR or sensor ports
Mounting: Global Connect chassis
Setup
First Use: With no DHCP server after two minutes the module takes 192.168.1.70 plus its chassis position. Each module is its own device with its own IP address. Up to 8 clients on port 4998; opening one more closes the oldest. Port 3's default mode differs by document; read it with GET PORT_MODE 3.
Support
Tech Support Phone: 541-899-4800
Power Cycle: Remove power for ten seconds. Relay states return to open after a reset or power cycle.
About this driver
driver.source()
Confirm each command on your device before you rely on it. Provided as is, with no warranty. To correct something or ask for it to come down, write to info@ctrlbot.io. Licensed CC BY 4.0: credit CTRLbot and link back when you share it. Product page. Manufacturer site.